SC2290/rev. 07-24 © 2024 USG Corporation and/or its af liates. All rights reserved. Printed in USA Manufactured by USG Interiors, LLC 550 West Adams Street Chicago, IL 60661 YEAR LIMITED SYSTEM WARRANTY • No Visible Sag • Mold/Mildew Protection BALANCED ACOUSTICS YEAR AVAILABILITY 22111, 22121, 22127, 22311 HIGH RECYCLED CONTENT Notice The information in this document is subject to change without notice. CGC Inc. or USG Corp. assumes no responsibility for any errors that may inadvertently appear in this document. ORDER SAMPLES/LITERATURE USG: usg.com or
[email protected] CGC: contact Sales Representative TECHNICAL SERVICES 800 USG.4YOU (874-4968) FOR MOST UP-TO-DATE TECHNICAL INFORMATION AND LEED REPORT TOOL usgdesignstudio.com cgcdesignstudio.com usg.ecomedes.com PRODUCT CERTIFIED FOR LOW CHEMICAL EMISSIONS: UL.COM/GG UL 2818 USG RADAR™ HIGH-NRC/HIGH-CAC ACOUSTICAL PANELS CLIMAPLUS™ PERFORMANCE UL Classifi ed Edge Panel Size Fire Rating2,9 Item No. NRC CAC Min. LR3 Color6 Grid Options VOC Emissions Anti-Mold & Mildew Recycled Content1 Panel Cost USG RADAR™ HIGH-CAC PANEL SQ 2'x4'x5/8" 22310 0.55 40 0.84 White A Low 57% $$ USG RADAR™ HIGH-NRC PANEL5,10 SQ 2'x2'x7/8" Class A 22421 0.70 35 0.84 White B,C,D,H,I,J Low 51% $$ 2'x2'x3/4" 22111 0.70 35 0.84 White A,K,L Low 63% $$ 2'x4'x3/4" 22311 0.70 35 0.84 White A Low 63% $$ SLT 2'x2'x7/8" Class A 22350 0.70 35 0.84 White E Low 51% $$ 2'x2'x3/4" 22121 0.70 35 0.84 White F Low 63% $$ 2'x4'x3/4" 22122 0.70 35 0.84 White F Low 63% $$ FLB 2'x2'x7/8" Class A 22370 0.70 35 0.84 White D,H,I,J Low 51% $$ 2'x2'x3/4" 22127 0.70 35 0.84 White K,L Low 63% $$ USG RADAR™ HIGH-NRC/HIGH-CAC PANELS5,10 SQ 2'x2'x3/4" 22521 0.70 40 0.84 White A,K,L Low 63% $$ 2'x4'x7/8" Class A 22441 0.70 40 0.84 White B,C Low 51% $$ 2'x4'x3/4" 22541 0.70 40 0.84 White A Low 63% $$ SLT 2'x2'x3/4" 22523 0.70 40 0.84 White F Low 63% $ 2'x4'x7/8" Class A 22360 0.70 40 0.84 White E Low 51% $$ FLB 2'x2'x3/4" 22527 0.70 40 0.84 White K,L Low 63% $$ Low Emissions (VOC) Third party (GREENGUARD Gold) certifi ed for low-emitting performance, meets California Department of Public Health’s (CDPH) Standard Method v1.2 - 2017 (CA Section 01350). ‘Certifi cates of Compliance’ for Low VOC Emissions are available on usg.ecomedes.com and at spot.ul.com. ClimaPlus™ Warranty Performance4 Contains a broad-spectrum antimicrobial additive on the face and back of the panel that provides resistance against the growth of mold and mildew. Includes sag-resistance performance. High Recycled Content USG classifi es High Recycled Content as greater than 50%. Total recycled content is based on product composition of pre-consumer (post-industrial) and post-consumer recycled content per FTC guidelines. Firecode® GRID PROFILE OPTIONS A USG DXL™ B USG DX® C USG DXW™ D7 USG Centricitee™ DXT™ E USG DX® F USG DXL™ G USG Fineline® DXF™ H USG Fineline® 1/8 DXFF™ I USG Identitee® DXI™ J USG Centricitee™ DXLT™ K USG Fineline® DXLF™ PHYSICAL DATA/ FOOTNOTES Product literature Data sheet: SC2290 ASTM E1264 classifi cation ASTM E1264-22 Type III, Form 2, Pattern C & E ASTM E1264-23 Type A, Form A1.2, Pattern C & E ASTM E84 and CAN/ULC S102 surface-burning characteristics Class A Flame spread: 25 or less Smoke developed: 50 or less UL Type FR-83 Online tools usgdesignstudio.com, cgcdesignstudio.com or usg.ecomedes.com Weight 0.90–1.28 lb./sq. ft. Thermal resistance R-1.6 (5/8" panels) R-1.9 (3/4" panels) R-1.8 (7/8" panels) Maximum backloading See USG 30-Year Limited System Warranty Commercial Applications (SC2102). Maintenance Panels can be cleaned easily with a soft brush or vacuum. Notes 1. For details, see USG Sustainabilty tool at usgdesignstudio.com or cgcdesignstudio.com. 2. Firecode® products are approved for use in fi re- resistance rated UL designs, where the designs allow for the UL Type Designation. 3. LR values are shown as averages. 4. For details, see USG 30-Year Limited System Warranty Commercial Applications (SC2102). 5. Helps comply with ANSI S12.60 classroom guidelines. 6. No Flat Black or "Deeptones" are available on reveal edge or USG RadarTM Firecode® panel. 7. Maximum 2'x2' with SQ edge panels. 8. This product has achieved both BioPreferred initiatives: Federal Procurement Preference and Certifi ed Product Labeling. See the complete listing of all USG ceiling panels on biopreferred.gov website. 9. It is not recommended to mix Firecode™ with Class A panels in the same ceiling plane. 10. It is not recommended to mix USG Radar™ High-NRC panels (0.70 NRC) with Radar ™ panels of varying NRC values in the same ceiling plane. The trademarks USG, CGC, CENTRICITEE, CLIMAPLUS, DONN, DX, DXF, DXFF, DXI, DXL, DXLF, DXLT, DXT, DXW, FINELINE, FIRECODE, IDENTITEE, RADAR, IT’S YOUR WORLD. BUILD IT., the USG/CGC logo, the design elements and colors, and related marks are trademarks of USG Corporation or its af liates. Safety First! Follow good safety/industrial hygiene practices during installation. Wear appropriate personal protective equipment. Read SDS and literature before specifi cation and installation. Acoustical Ceiling Panels 283
ceilings systems catalog sc2000
Title Name |
Pages |
Delete |
Url |
Empty |
Search Text Block
Page #page_num
#doc_title
Hi $receivername|$receiveremail,
$sendername|$senderemail wrote these comments for you:
$message
$sendername|$senderemail would like for you to view the following digital edition.
Please click on the page below to be directed to the digital edition:
$thumbnail$pagenum
$link$pagenum