AC3029/rev. 8-24 © 2024 USG Corporation and/or its af liates. All rights reserved. Printed in U.S.A. Manufactured by USG Interiors, LLC 550 West Adams Street Chicago, IL 60661 YEAR LIMITED SYSTEM WARRANTY • No Visible Sag • Mold/Mildew Protection Notice The information in this document is subject to change without notice. CGC Inc. or USG Corp. assumes no responsibility for any errors that may inadvertently appear in this document. ORDER SAMPLES/LITERATURE USG: usg.com or
[email protected] CGC: contact Sales Representative TECHNICAL SERVICES 800 USG.4YOU (874-4968) FOR MOST UP-TO-DATE TECHNICAL INFORMATION AND LEED REPORT TOOL usgdesignstudio.com cgcdesignstudio.com usg.ecomedes.com Declare® Labels on select fi nishes, see usg.ecomedes.com for more details and documentation. Seismic Design Category 1,5 Rated Load 2 ASTM Class Length Height Item No. Fire Rating Color IBC ICC-ES Evaluated Installation 4' Hanger Spacing 5' Hanger Spacing 6' Hanger Spacing 15/16" TEE SYSTEM4 Main Tee Intermediate Duty2 12' USG 1.64" 42 mm CGC 1.5" 25 mm ZXLA24 Flat White Flat Black Satin Silver A–C 7/8" Molding ACM7 Clip 12 lb./LF 6.3 lb./LF 3.7 lb./LF Heavy Duty 12' USG 1.64" 42 mm ZXLA26 Flat White Flat Black Satin Silver A–F 7/8" Molding ACM7 Clip 16 lb./LF 8.3 lb./LF 4.9 lb./LF Cross Tee 1 -1/2" (38 mm) — 2' 1-1/2" 38 mm ZXLA224 Flat White Flat Black Satin Silver — — — — — 4' 1-1/2" 38 mm ZXLA424 Flat White Flat Black Satin Silver — — — — — Low Emissions (VOC) CDPH 01350 v1.2-2017 compliance on select fi nishes, see usg.ecomedes.com for more details and documentation. Firecode® Wall Angle Length Item No. Color MOLDING3 7 8/ " 7 8/ " 12' M7Z Flat White Flat Black Satin Silver PHYSICAL DATA/ FOOTNOTES Product literature and samples Data sheet: AC3029 Exterior systems guide: SC2561 Material G90 hot-dipped galvanized steel tee and aluminum cap; stainless steel clip. Baked on polyester paint or powder coated fi nish. Installation Install according to ASTM C636, ASTM E580, CISCA and USG requirements. Alternate installation methods may be used when approved by the authority having jurisdiction. Online tools usgdesignstudio.com, cgcdesignstudio.com or usg.ecomedes.com ICC Evaluation Report for Code Compliance See ICC-ES Evaluation Report ESR-1222 for allowable values and conditions of use in seismic design categories A through F. Reports are subject to reexamination, revision and possible cancellation. Refer to usg.com for most current version. ASTM Load Compliance Classifi ed as Light, Intermediate or Heavy Duty per ASTM C635 when tested and evaluated in accordance with ASTM E3090 and AC368. Limitations Finish is not UV-resistant; should not be installed where direct exposure to sun or weather will occur, such as fascias or facades. Not suitable for areas subject to high concentrations of acid rain. Indirect exposure to severe environmental conditions may shorten the life span of the product. The specifi c design of exterior ceiling installations requires the review and approval of the architect or engineer of record. Please refer to SC2561 for more information about exterior ceiling applications. Notes 1. All USG main tees, cross tees and main tee-hanger wire connections meet AC 368 and ASTM E580 requirements for tension and compression strength, as tested per ASTM E3090. 2. Rated Load expressed in lb./LF based on simple span tests in accordance with ASTM E3090 with defl ection limit of L/360. Duty rating is assigned based on rated load per ASTM C635. 3. Panels must be specifi ed to be fi eld-cut to size and fi eld-revealed to provide as wide a lay-on edge as possible. 4. Metric sizes available by RTQ. 5. Seismically tested in accordance with ASTM E3118. USG DONN® BRAND ZXLA™ ACOUSTICAL SUSPENSION SYSTEM The trademarks USG, CGC, CLIMAPLUS, DONN, ECLIPSE, FIRECODE, QUICK-RELEASE, ZXLA, IT'S YOUR WORLD. BUILD IT., the USG/ CGC logo, the design elements and colors, and related marks are trademarks of USG Corporation or its af liates. Safety First! Follow good safety/industrial hygiene practices during installation. Wear appropriate personal protective equipment. Read SDS and literature before specifi cation and installation. Suspension Systems 341
ceilings systems catalog sc2000
Title Name |
Pages |
Delete |
Url |
Empty |
Search Text Block
Page #page_num
#doc_title
Hi $receivername|$receiveremail,
$sendername|$senderemail wrote these comments for you:
$message
$sendername|$senderemail would like for you to view the following digital edition.
Please click on the page below to be directed to the digital edition:
$thumbnail$pagenum
$link$pagenum