AC3036/rev. 8-24 © 2024 USG Corporation and/or its af liates. All rights reserved. Printed in USA Manufactured by USG Interiors, LLC 550 West Adams Street Chicago, IL 60661 YEAR LIMITED SYSTEM WARRANTY • No Visible Sag • Mold/Mildew Protection Notice The information in this document is subject to change without notice. CGC Inc. or USG Corp. assumes no responsibility for any errors that may inadvertently appear in this document. ORDER SAMPLES/LITERATURE USG: usg.com or
[email protected] CGC: contact Sales Representative TECHNICAL SERVICES 800 USG.4YOU (874-4968) FOR MOST UP-TO-DATE TECHNICAL INFORMATION AND LEED REPORT TOOL usgdesignstudio.com cgcdesignstudio.com usg.ecomedes.com Seismic Design Category 1, 10 Rated Load 2 ASTM Class Length Height Item No. Fire Rating4 Color3 IBC ICC-ES Evaluated Installation 4' Hanger Spacing 5' Hanger Spacing USG DONN® BRAND DXLA™ 15/16” TEE SYSTEM8 Main Tee Cross Tee 1” Cross Tee 1-1.2” Intermediate Duty 12' USG 1.64” 42 mm/ CGC 1.5” 25mm DXLA24 Flat White Silver Satin A–C 7/8" Molding ACM7 Clip 12 lb./LF 6.1 lb./LF Heavy Duty 12' USG 1.64” 42 mm/ CGC 1.5” 38 mm DXLA26 Flat White Silver Satin A–F 7/8" Molding ACM7 Clip 16 lb./LF 7.3 lb./LF 2' 1” 25 mm DXLA216 Flat White Silver Satin 4' 1-1/2” 38 mm DXLA424 Flat White Silver Satin USG DONN® BRAND DXACE™ 15/16” TEE SYSTEM8,9 Main Tee Cross Tee 1-1.2” Heavy Duty 12' USG 1.64” 42 mm/ CGC 1.5” 25mm DXACE26 Class A Flat White6 A–F 7/8" Molding ACM7 Clip 16 lb./LF 7.3 lb./LF 2' 1-1/2” 38 mm DXACE224 Class A Flat White6 4' 1-1/2” 38 mm DXACE424 Class A Flat White6 WALL ANGLE6 Molding5 Length Item No. Hold-Down Clips7 Color Wall Angle Length Item No. Color Hold-Down Clips7 1" 1" 10’ MC11A25 Flat White 7 8/ " 7 8/ " 12’ M7Z Flat White Silver Satin — 7 8/ " 7 8/ " 12’ M7A — Flat White 7/8" 7/8" 12’ M7ACE Flat White L15/L15CE 1/2" 1" 111/16" 10’ US28CE C-8/C-8CE Clean Room Installation Install according to ASTM C636, ASTM E580, CISCA and USG requirements. Alternate installation methods may be used when approved by the authority having jurisdiction. Must be installed in compliance with ASTM C636, ASTM E580, CISCA and standard industry practices, within all applicable code requirements. Class 5-8 (Fed. Standard 209E Class 100-100,000) installations require hold-down clips and US28CE molding. Install a L15 hold-down clip within 3 in. of each panel corner. For a 2’ x 4’ system install an additional L15 hold-down clip centered on the 4’ side. Border panels shall have a C-8 hold-down clip within 3 in. of each panel corner. For a 2’ x 4’ system install an additional C-8 hold-down clip centered on the 4’ side. Alternative assemblies and installation methods may be utilized when approved by the authority having jurisdiction. Low Emissions (VOC) CDPH 01350 v1.2-2017 compliance on select fi nishes, see usg.ecomedes.com for more details and documentation. Firecode® PHYSICAL DATA/ FOOTNOTES Product literature and samples Data sheet: AC3036 USG Donn® Brand DXLA™ sample: 215675 Online tools usgdesignstudio.com, cgcdesignstudio.com or usg.ecomedes.com Material Min. G30 hot-dipped galvanized steel body and aluminum cap. Baked-on polyester paint or powder-coated fi nish. Installation Interior applications only. Please refer to SC2561 for more information about exterior ceiling applications. The gasket face applied to USG Donn® Brand DXACE™ contains a protective strip that must be removed prior to panel installation. The standard gasket is not recommended for installations with metal panels. If metal panels are desired, a special gasket suitable for metal panels may be applied to the USG Donn® Brand DXACE™ suspension system through special order. ICC Evaluation Report for Code Compliance See ICC-ES Evaluation Report ESR-1222 for allowable values and conditions of use in seismic design categories A through F. Reports are subject to reexamination, revision and possible cancellation. Refer to usg.com for most current version. ASTM Load Compliance Classifi ed as Light, Intermediate or Heavy Duty per ASTM C635 when tested and evaluated in accordance with ASTM E3090 and AC368. Healthcare facilities – Capable of withstanding cleaning and/or disinfecting chemicals as tested in accordance with ASTM D5402-06. Notes 1. All USG main tees, cross tees and main tee-hanger wire connections meet AC 368 and ASTM E580 requirements for tension and compression strength, as tested per ASTM E3090. 2. Rated Load expressed in lb./LF based on simple span tests in accordance with ASTM E3090 with defl ection limit of L/360. Duty rating is assigned based on rated load per ASTM C635. 3. Some products available in custom colors. USG Donn® Brand DXACE™ available in fl at white only. 4. For fi re-rated ceilings, must be installed as stated in UL designs. 5. Channel moldings also acceptable in some UL designs. 6. Panels must be fi eld-cut to size at the perimeter. For Shadowline detail, fi eld-cut edge must be at least as wide as the factory cut. 7. US28CE molding and L15 and C-8 hold-down clips required for Clean Room ISO Class 5 (Fed. Standard 209E Class 100) applications. 8. Metric sizes available by RTQ. 9. DXACE™ products are not available in Powder Coated paint options. 10. Seismically tested in accordance with ASTM E3118. USG DONN® BRAND DXLA™/DXACE™ ACOUSTICAL SUSPENSION SYSTEM The trademarks USG, CGC, DONN, DXACE, DXLA, ECLIPSE, ECOBLUEPRINT, FIRECODE, QUICK-RELEASE, IT’S YOUR WORLD. BUILD IT., the USG/CGC logo, the design elements and colors, and related marks are trademarks of USG Corporation or its af liates. Safety First! Follow good safety/industrial hygiene practices during installation. Wear appropriate personal protective equipment. Read SDS and literature before specifi cation and installation. CDPH 01350 v1.2-2017 compliant, see usg.com for more details and documentation Suspension Systems 337
ceilings systems catalog sc2000
Title Name |
Pages |
Delete |
Url |
Empty |
Search Text Block
Page #page_num
#doc_title
Hi $receivername|$receiveremail,
$sendername|$senderemail wrote these comments for you:
$message
$sendername|$senderemail would like for you to view the following digital edition.
Please click on the page below to be directed to the digital edition:
$thumbnail$pagenum
$link$pagenum