AC3041/rev. 8-24 © 2024 USG Corporation and/or its af liates. All rights reserved. Printed in U.S.A. Manufactured by USG Interiors, LLC 550 West Adams Street Chicago, IL 60661 Notice The information in this document is subject to change without notice. CGC Inc. or USG Corp. assumes no responsibility for any errors that may inadvertently appear in this document. YEAR LIMITED SYSTEM WARRANTY • No Visible Sag • Mold/Mildew Protection ORDER SAMPLES/LITERATURE USG: usg.com or
[email protected] CGC: contact Sales Representative TECHNICAL SERVICES 800 USG.4YOU (874-4968) FOR MOST UP-TO-DATE TECHNICAL INFORMATION AND LEED REPORT TOOL usgdesignstudio.com cgcdesignstudio.com usg.ecomedes.com USG DONN® BRAND AX™/AXCE™ ACOUSTICAL SUSPENSION SYSTEM The trademarks USG, CGC, AX, AXCE, CLIMAPLUS, DONN, DXACE, ECLIPSE, QUICK-RELEASE, IT’S YOUR WORLD. BUILD IT., the USG/CGC logo, the design elements and colors, and related marks are trademarks of USG Corporation or its af liates. Safety First! Follow good safety/industrial hygiene practices during installation. Wear appropriate personal protective equipment. Read SDS and literature before specifi cation and installation. Seismic Design Category1,7,8 Rated Load 2 ASTM Class Length Height Item No. Fire Rating Color IBC ICC-ES Approved Installation 2' Hanger Spacing 30" Hanger Spacing 3' Hanger Spacing 4' Hanger Spacing USG DONN® BRAND AX™ 15/16" TEE SYSTEM5 Main Tee Light Duty 12' 1-1/2" 38 mm AX26 Class A Flat White A-F 7/8" Molding ALACM7 Clip 35 lb./LF 18.7 lb./LF 11.2 lb./LF 5 lb./LF Cross Tee 2' 1-1/2" 38 mm AX224 Class A Flat White 4' 1-1/2" 38 mm AX424 Class A Flat White USG DONN® BRAND AXCE™ 15/16" TEE SYSTEM5,6 Main Tee Light Duty 12' 1-1/2" 38 mm AXCE26 Class A Flat White A-F 7/8" Molding ALACM7 Clip 35 lb./LF 18.7 lb./LF 11.2 lb./LF 5 lb./LF Cross Tee 2' 1-1/2" 38 mm AXCE224 Class A Flat White 4' 1-1/2" 38 mm AXCE424 Class A Flat White MOLDING 3, 4 Wall Angle Length Item No. Color Perimeter Channel Length Item No. Color 7 8/ " 7 8/ " 12' M7A Flat White 10' UA25 Flat White 7/8" 7/8" 12' M7ACE Flat White 1/2" 1" 19/16" 10' UA25CE Flat White Low Emissions (VOC) CDPH 01350 v1.2-2017 compliance on select fi nishes, see usg.ecomedes.com for more details and documentation. PHYSICAL DATA/ FOOTNOTES Product literature and samples Data sheet: AC3041 Technical Guide: AC329917 USG Donn® Brand AX™ sample: 272638 USG Donn® Brand AXCE™ sample: 216857 Product information See usg.com for the most up-to-date product information. Material Double-web aluminum tee with aluminum cap and stainless steel Quick-Release™ clip. Baked-on polyester paint. Installation Install according to ASTM C636, ASTM E580, CISCA and USG requirements. Alternate installation methods may be used when approved by the authority having jurisdiction. ICC Evaluation Report for Code Compliance See ICC-ES Evaluation Report ESR-1222 for allowable values and conditions of use in seismic design categories A through F. Reports are subject to reexamination, revision and possible cancellation. Refer to usg.com for most current version. ASTM Load Compliance Classifi ed as Light, Intermediate or Heavy Duty per ASTM C635 when tested and evaluated in accordance with ASTM E3090 and AC368. Online tools usgdesignstudio.com, cgcdesignstudio.com or usg.ecomedes.com Limitations Non-fi re-rated applications only. Finish is not UV-resistant; should not be installed where direct exposure to sun or weather will occur, such as fascias or facades. Indirect exposure to severe environmental conditions may shorten the lifespan of the product. The gasket face applied to USG Donn® Brand AXCE™ contains a protective strip that must be removed prior to panel installation. The standard gasket is not recommended for installations with metal panels. If metal panels are desired, a special gasket suitable for metal panels may be applied to the USG Donn® Brand DXACE™ suspension system through special order. Clean Room Installation Must be installed in compliance with ASTM C636, ASTM E580, CISCA and standard industry practices, within all applicable code requirements. Class 5-8 (Fed. Standard 209E Class 100-100,000) installations require holddown clips and US28CE molding. Install a L15 hold-down clip within 3 in. of each panel corner. For a 2' x 4' system install an additional L15 hold-down clip centered on the 4' side. Border panels shall have a C-8 hold-down clip within 3 in. of each panel corner. For a 2' x 4' system install an additional C-8 hold-down clip centered on the 4' side. Alternative assemblies and installation methods may be utilized. Seismic and heavy duty applications See SC2499. Notes 1. All USG main tees, cross tees and main tee-hanger wire connections meet AC 368 and ASTM E580 requirements for tension and compression strength, as tested per ASTM E3090. 2. Rated Load expressed in lb./LF based on simple span tests in accordance with ASTM E3090 with defl ection limit of L/360. Duty rating is assigned based on rated load per ASTM C635. 3. Perimeter panels must be trimmed so that the edge extends completely over the gasket 4. UA25CE molding and L15 and C8 hold-down clips are required for ISO Class 5 Clean Room applications. 5. Metric sizes available by RTQ. 6. AXCE™ is not available in powder coated options, only available in Standard and Advantage options. 7. For seismic installation requirements refer to ESR-1222 8. Seismically tested in accordance with ASTM E3118. Suspension Systems 333
ceilings systems catalog sc2000
Title Name |
Pages |
Delete |
Url |
Empty |
Search Text Block
Page #page_num
#doc_title
Hi $receivername|$receiveremail,
$sendername|$senderemail wrote these comments for you:
$message
$sendername|$senderemail would like for you to view the following digital edition.
Please click on the page below to be directed to the digital edition:
$thumbnail$pagenum
$link$pagenum