AC3037/rev. 8-24 © 2024 USG Corporation and/or its af liates. All rights reserved. Printed in U.S.A. Manufactured by USG Interiors, LLC 550 West Adams Street Chicago, IL 60661 Notice The information in this document is subject to change without notice. CGC Inc. or USG Corp. assumes no responsibility for any errors that may inadvertently appear in this document. YEAR LIMITED SYSTEM WARRANTY • No Visible Sag • Mold/Mildew Protection ORDER SAMPLES/LITERATURE USG: usg.com or
[email protected] CGC: contact Sales Representative TECHNICAL SERVICES 800 USG.4YOU (874-4968) FOR MOST UP-TO-DATE TECHNICAL INFORMATION AND LEED REPORT TOOL usgdesignstudio.com cgcdesignstudio.com usg.ecomedes.com Declare® Labels on select fi nishes, see usg.ecomedes.com for more details and documentation. USG DONN® BRAND DXW™ ACOUSTICAL SUSPENSION SYSTEM Seismic Design Category 1,6 Rated Load2 ASTM Class Length Height Item No. Fire Rating Color 3 IBC ICC-ES Evaluated Installation 4' Hanger Spacing 5' Hanger Spacing 6' Hanger Spacing 1-1/2" TEE SYSTEM Main Tee Heavy Duty 12' 1-1/2" 38 mm DXW26 Class A Standard A-F 7/8" Molding ACM7 Clip 16 lb./LF 8.5 lb./LF 5 lb./LF Cross Tee 1-1/2" 2' 1-1/2" 38 mm DXW224 Class A Standard — — 36.7 lb./LF — — 4' 1-1/2" 38 mm DXW424 Class A Standard — — 13.8 lb./LF — — MOLDING4,5 Wall Angle Length Item No. Color Wall Angle Length Item No. Color 7 8/ " 7 8/ " 12' M7 Standard 2" 1" 10' 3000 mm M20 Flat White 11/2" 1" 12' M12 Standard Low Emissions (VOC) CDPH 01350 v1.2-2017 compliance on select fi nishes, see usg.ecomedes.com for more details and documentation. PHYSICAL DATA/ FOOTNOTES Product literature and samples Data sheet: AC3037 Sample: 219168 Material Min. G30 hot-dipped galvanized steel body and cap. Baked-on polyester paint or powder-coated fi nish. Installation Install according to ASTM C636, ASTM E580, CISCA and USG requirements. Alternate installation methods may be used when approved by the authority having jurisdiction. Online tools usgdesignstudio.com, cgcdesignstudio.com or usg.ecomedes.com ICC Evaluation Report for Code Compliance See ICC-ES Evaluation Report ESR-1222 for allowable values and conditions of use in seismic design categories A through F. Reports are subject to reexamination, revision and possible cancellation. Refer to usg.com for most current version. ASTM Load Compliance Classifi ed as Light, Intermediate or Heavy Duty per ASTM C635 when tested and evaluated in accordance with ASTM E3090 and AC368. Notes 1. All USG main tees, cross tees and main tee-hanger wire connections meet AC 368 and ASTM E580 requirements for tension and compression strength, as tested per ASTM E3090. 2. Rated Load expressed in lb./LF based on simple span tests in accordance with ASTM E3090 with defl ection limit of L/360. Duty rating is assigned based on rated load per ASTM C635. 3. Custom colors available. 4. For more information on moldings, see Perimeter Interface selector. 5. Panels must be fi eld-cut to size at the perimeter. 6. Seismically tested in accordance with ASTM E3118. The trademarks USG, CGC, CLIMAPLUS, DONN, DXW, ECLIPSE, QUICK-RELEASE, IT’S YOUR WORLD. BUILD IT., the USG/CGC logo, the design elements and colors, and related marks are trademarks of USG Corporation or its af liates. Safety First! Follow good safety/industrial hygiene practices during installation. Wear appropriate personal protective equipment. Read SDS and literature before specifi cation and installation. Suspension Systems 319
ceilings systems catalog sc2000
Title Name |
Pages |
Delete |
Url |
Empty |
Search Text Block
Page #page_num
#doc_title
Hi $receivername|$receiveremail,
$sendername|$senderemail wrote these comments for you:
$message
$sendername|$senderemail would like for you to view the following digital edition.
Please click on the page below to be directed to the digital edition:
$thumbnail$pagenum
$link$pagenum