ORDER SAMPLES/LITERATURE USG: usg.com or
[email protected] CGC: contact Sales Representative TECHNICAL SERVICES 800 USG.4YOU (874-4968) FOR MOST UP-TO-DATE TECHNICAL INFORMATION AND LEED REPORT TOOL usgdesignstudio.com cgcdesignstudio.com usg.ecomedes.com YEAR LIMITED SYSTEM WARRANTY • No Visible Sag • Mold/Mildew Protection HIGH RECYCLED CONTENT Declare® Labels on select finishes, see usg.ecomedes.com for more details and documentation. AC3034/rev. 7-25 © 2025 USG Corporation and/or its affiliates. All rights reserved. Printed in U.S.A. Manufactured by USG Interiors, LLC 550 West Adams Street Chicago, IL 60661 Notice The information in this document is subject to change without notice. CGC Inc. or USG Corp. assumes no responsibility for any errors that may inadvertently appear in this document. Wall Angle Length Item No. Color MOLDING9,10, 13 7 8/ " 7 8/ " 12’ 3600 mm M7 Flat White Standard Advantage 9/16" 15/16" 12' 3600 mm M9 Flat White, Standard, Advantage, Premium M9 HRC Flat White, Standard, Advantage, Premium Shadowline9,10 3/8" 7/8" 3/8" 9/16" 12' MS174 Flat White, Standard, Advantage, Premium MS174HRC Low Emissions (VOC) CCertified for low emitting performance, meets CDPH 01350 v1.2 - 2017. Certificates of Compliance for Low VOC Emissions are available on usg.com and at usg.ecomedes.com. High Recycled Content USG classifies High Recycled Content as greater than 50%. Methodology of calculation based on FTC guidelines. USG DONN® BRAND FINELINE® DXF™/DXLF™ ACOUSTICAL SUSPENSION SYSTEM The trademarks USG, CGC, CELEBRATION, CLIMAPLUS, DONN, DXF, DXFEV, DXLF, ECLIPSE, ECOBLUEPRINT, FINELINE, FIRECODE, LOGIX, ZXLA, IT'S YOUR WORLD. BUILD IT., the USG/CGC logo, the design elements and colors, and related marks are trademarks of USG Corporation or its affiliates. Safety First! Follow good safety/industrial hygiene practices during installation. Wear appropriate personal protective equipment. Read SDS and literature before specification and installation. PHYSICAL DATA Product literature and samples Technical data: AC272 Sample: 204105 Installation Install according to ASTM C636, ASTM E580, CISCA and USG requirements. Alternate installation methods may be used when approved by the authority having jurisdiction. Limitations For exposed grids in non-fire-rated, high-humidity applications, use USG Donn® Brand Fineline® DXFEV™ G90 painted suspension system. For exterior applications, the suspension system should be reviewed by a structural engineer. Please refer to SC2561 for more information about USG Donn® Brand Fineline® DXFEV™ and exterior ceiling applications. Online tools usgdesignstudio.com, cgcdesignstudio.com or usg.ecomedes.com Material Min. G30 hot-dipped galvanized steel body. Baked-on polyester paint. ICC Evaluation Report for Code Compliance See ICC-ES Evaluation Report ESR-1222 for allowable values and conditions of use in seismic design categories A through F. Reports are subject to reexamination, revision and possible cancellation. Refer to usg.com for most current version. ASTM Load Compliance Classified as Light, Intermediate or Heavy Duty per ASTM C635 when tested and evaluated in accordance with ASTM E3090 and AC368. Notes 1. All USG main tees, cross tees and main tee-hanger wire connections meet AC 368 and ASTM E580 requirements for tension and compression strength, as tested per ASTM E3090. 2. Rated Load expressed in lb./LF based on simple span tests in accordance with ASTM E3090 with deflection limit of L/360. Duty rating is assigned based on rated load per ASTM C635. 3. Some products are available in metric. Call Customer Service for details. 4. Custom color available. 5. Standard main tee is notched 24" o.c. but has cross-tee holes 12" o.c. 6. Cross-tee hole spacings available for a variety of modules except USG Donn® Brand Fineline® DXLF™. 7. N = Notch at midpoint. 8. S = Midpoint notch on one side only to accomodate light fixture. 9. For more information about moldings, see Perimeter Interface selector. 10. Panels must be field-cut to size at the perimeter. 11. Notched 30" o.c. 12. Notched 20" o.c. 13. Metric sizes listed available with standard lead times. Other metric sizes available by RTQ. 14. Seismically tested in accordance with ASTM E3118 and AC156. 304
ceilings systems catalog sc2000
| Title Name |
Pages |
Delete |
Url |
| Empty |
Ai generated response may be inaccurate.
Search Text Block
Page #page_num
#doc_title
Hi $receivername|$receiveremail,
$sendername|$senderemail wrote these comments for you:
$message
$sendername|$senderemail would like for you to view the following digital edition.
Please click on the page below to be directed to the digital edition:
$thumbnail$pagenum
$link$pagenum